micro DL-500 Self-Leveling 5-Dot Laser
11
SYMPTOM POSSIBLE REASON SOLUTION
The unit not self-
leveling.
The unit is locked. Turn the ON/OFF switch (I/O) clockwise
to unlock the unit.
Laser beam ashing. Unit not level enough. Mount the unit in the range of ±4.5°
slope for self-level.
Power indication
lamp ashing.
Battery voltage low. Replace batteries.
Unit will not turn ON. Dead batteries. Replace batteries.