Installation
The machine should have its own dedicated supply, unless the line supply is known to be clean. The
earth should be robust, of low impedance and noise free.
Any dedicated supply line should be run in its own conduit / trunking away from other noisy supplies.
The input voltage should not be subject to voltage fluctuations outside the limits (NWML0320):
Minus 15% to plus 10% of the nominal supply voltage (230V or 110V).
Zero voltage for more than 20mS.
50% of nominal voltage for more than 40mS.
80% of nominal voltage for more than 100mS.
Operation outside these limits may cause loss of function until the supply condition recovers to within
limits.
The standard metal detector conveyor is fitted with a starter isolator and a 24V ac control circuit. The
supply voltage for the conveyor is indicated on the identification plate that is mounted on the frame.
The following illustration shows the isolator inside a typical electrical services box
The Isolator Switch can be locked in the OFF’ position using a padlock to prevent electrical
power being restored whilst carrying out servicing and maintenance activities.
To connect an electrical supply, proceed as follows:
1. Unlock and open the Electrical Services Box to access the electrical services.
2.
The back of the Isolator Switch is located in the bottom right hand side of the cabinet
when viewed from the rear. Beneath it on the bottom of the cabinet is the cable gland
access for the power cable.
3. Push the supply cable up into the Electrical Services Box through the cable gland.
4.
Split the cable inside the box and cut the wires to suitable lengths. An armoured/braided
cable is recommended when cable conduit is not used. A suitable earth conductor is
also to be fitted.
5.
Crimp connectors onto the wires and connect to the Isolator Switch as specified in the
table below.
6. Check that all connections are secure then refit the metal cover plate and front cover.