Operating Instructions
Update Learn
This process is only available if you have previously carried out a Full Learn process for the
product. It fine-tunes the phase value to minimize the signal, while still checking for metal in
the product. Use an Update Learn to update the signal when the production line is running if
false rejects are occurring because the signal has drifted.
See the Update Learn section for further details.
Reverse Learn
This process is only available if the Reverse Mode option has been enabled in the Menus >
Service > Options menu screen. It is used in situations where for example a product must
contain a contaminant, perhaps a toy car or whistle, and the metal detector is being used to
reject products that do not contain one.
Both the Full and Update Learn processes can be selected and run from the Learn Set Up
menu when the detector is in Reverse Mode.
See also the Learn Messages
section which lists the messages that may be displayed by the metal
detector during a Learn process and provides an explanation for each one.
Full Learn
Prior to carrying out a Full Learn, ensure that you have a number of representative sample products
available to pass through the detector as part of the process.
The Learn process utilises the currently selected product so ensure that you select the correct product
through the Menus > Change menu before continuing.
To perform a Full Learn for a product, proceed as follows:
1.
Select Menus > Learn to display the
Learn menu and select the Full option.
2.
Press the OK / Enter Key to start the Full
Learn process. The name and number of
the product being learnt are displayed.
3.
A 'WAIT' message is then displayed.
4.
This is followed by a 'PASS PRODUCT'
message.
5.
When the 'PASS PRODUCT' message is displayed, start to pass products through the detector.
6.
A 'Learning' message is then displayed,
along with a number which signifies either
the time in seconds remaining to pass
products if a Photo-eye is not fitted, or the
number of product packs remaining to be
passed if a Photo-eye is fitted.
7.
Once the Learn process is finished a
'Learn Complete' message is displayed.
Additional messages may be displayed during the Learn process which are listed and explained in the
Learn Messages
section.